Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered Automatic Transfer Switch PDU Two 200-240V L6-30P Inputs 16-C13 2-C19 & 1 L6-30R Outlet 2U TAA

by
TRIPP LITE
PCN#
KU6723
MFG#
PDUMH30HVAT
$644.60
cps

Extended & Accidental Damage Protection Plans Available Details

  Free Shipping
Estimated Shipment:

Calculating Shipping

Product Highlights:
  • 2UHorizontal Rackmount
Product Condition: New and Factory Fresh
Limited Warranty2 Year
Shipping Weight: 18 lbs.
Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered Automatic Transfer Switch PDU Two 200-240V L6-30P Inputs 16-C13 2-C19 & 1 L6-30R Outlet 2U TAA
Tech Specs
Specifications

Manufacturer

Tripp Lite by Eaton

Manufacturer Part Number

PDUMH30HVAT

Manufacturer Website Address

https://tripplite.eaton.com/

Brand Name

Tripp Lite by Eaton

Product Series

Metered

Product Model

PDUMH30HVAT

Product Name

Metered PDUMH30HVAT 19-Outlets PDU

Marketing Information

Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Product Type

PDU
Technical Information

Plug/Connector Type

NEMA L6-30P

Plug/Connector Detail

2 x NEMA L6-30P

Receptacle Type

  • NEMA L6-30R
  • IEC 60320 C19
  • IEC 60320 C13

Receptacle Detail

  • 1 x NEMA L6-30R
  • 2 x IEC 60320 C19
  • 16 x IEC 60320 C13
Power Description

Input Voltage

230 V AC

Input Voltage Range

208 V AC - 240 V AC

Output Voltage

  • 208 V AC
  • 240 V AC
Physical Characteristics

Mounting Orientation

Horizontal

Mount Type

Rack-mountable

Rack Height

2U

Number of Cord/Cable

2

Height

3.5"

Width

17.5"

Depth

12.5"

Weight (Approximate)

13.80 lb
Miscellaneous

Package Contents

  • Metered PDUMH30HVAT 19-Outlets PDU
  • Rackmount Installation Brackets
  • Installable Plug-retention Shelves
  • Cable Ties

Country of Origin

Taiwan

TAA Compliant

Yes

Environmentally Friendly

Yes

Environmental Compliance

Restriction of Hazardous Substances (RoHS)
Warranty

Limited Warranty

2 Year