Cisco 3G Lightning Arrestor

by
CISCO
PCN#
9684AJ
MFG#
3G-ACC-OUT-LA-RF
$109.26
cps

Extended & Accidental Damage Product Replacement Plan Available Details

  Free Shipping
Estimated Shipment:

Calculating Shipping

Product Highlights: No Description Found
Product Condition: New and Factory Fresh
Shipping Weight: 1 lbs.
Cisco 3G Lightning Arrestor
Tech Specs
Specifications

Manufacturer

Cisco Systems, Inc

Manufacturer Part Number

3G-ACC-OUT-LA-RF

Manufacturer Website Address

http://www.cisco.com

Brand Name

Cisco

Product Name

3G Lightning Arrestor

Marketing Information

The Cisco 3G-ACC-LA provides a level of safety protection to the user as well as to wireless equipment by shunting to ground over-voltage transients induced into outdoor antennas and cables. These transients, in mild cases can produce interfering signals in a wireless system, and in extreme cases, can be dangerous and destructive.

Overvoltage transients can be created through lightning static discharges, switch processes, direct contact with power lines, or through earth currents. The Cisco 3G-ACC-OUT-LA Lightning Arrestor limits the amplitude and duration of disturbing interference voltages and improves the overvoltage resistance of in-line equipment, systems, and components. A lightning arrestor installed according to these mounting instructions balances the voltage potential, thus providing safety and preventing inductive interference to parallel signal lines within the protected system.

The Cisco 3G-ACC-OUT-LA Lightning Arrestor is designed for use with Cisco 3G wireless devices and Cisco 4G wireless devices, and antennas and cables that use standard TNC connectors.

Product Type

Grounding Kit
Physical Characteristics

Product Material

Brass
Miscellaneous

Additional Information

Arrestor Type: Quarter wave high pass filter

Main path connectors:
Unprotected side: TNC jack (female)
Protected side: TNC plug (male)

Impedance: 50W

Frequency range: 800 MHz to 2200 MHz

Return loss: > 26 dB

Insertion loss: < 0.1 dB

RF CW power: < 20 W

Surge current handling capability: 20 single / 10 multiple kA (test pulse 8/20 ms)

Residual pulse energy:
.03 microjoules typically
(test pulse 4 kV 1.2/50 ms; 2kA 8/20 ms)

Operating temperature range: -40°F to 185°F (-40°C to 85°C)

Waterproof rating: IP67

Mouting and grounding: Bulkhead

Alternate grounding: Supplied ground lug and customer-provided 6 AWG, 20 inches maximum length ground wire

Material:
Housing: brass
Center contact: gold-plated brass