Tripp Lite by Eaton UPS 208V 5000VA 5000W On-Line Double-Conversion UPS Unity Power Factor with 120V Transformer Hardwire/L6-30P Input 5U

by
TRIPP LITE
PCN#
8JU205
MFG#
SU5KRT3UTF
$5,403.92
cps

Extended & Accidental Damage Protection Plans Available Details

Estimated Shipment:

Calculating Shipping

Product Highlights:
  • 3U Rack/Tower
  • 3 Hour Recharge
  • 5 Minute Stand
  • Show more

Product Condition: New and Factory Fresh
Limited Warranty2 Year
Shipping Weight: 261 lbs.
Tripp Lite by Eaton UPS 208V 5000VA 5000W On-Line Double-Conversion UPS Unity Power Factor with 120V Transformer Hardwire/L6-30P Input 5U
Tech Specs
Specifications

Manufacturer

Tripp Lite by Eaton

Manufacturer Part Number

SU5KRT3UTF

Manufacturer Website Address

https://tripplite.eaton.com/

Brand Name

Tripp Lite by Eaton

Product Line

SmartOnline

Product Model

SU5KRT3UTF

Product Name

SmartOnline SU5KRT3UTF 5kVA Rack/Tower UPS

Marketing Information

Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss

Tripp Lite's SU5KRT3UTF Unity Power Factor UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Unity Power Factor design enables full 5000VA / 5000W output capacity when used with hardwire 208V input power (output de-rates to 4800W with included L6-30P input cord option). In double-conversion mode, this UPS system maintains perfect output by continuously converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with ±1% voltage regulation and zero transfer time between online and battery modes. Featuring true on-line, double-conversion operation, Tripp Lite's SmartOnline® SU5KRT3UTF provides the highest level of UPS power protection for critical server, network and telecom equipment.

Reliable, Expandable Battery Backup

UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The internal battery set provides 15 minutes of support at half load and 5 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. Advanced temperature-controlled battery charge management system provides efficient recharge and enhanced battery lifespan. For mission-critical applications demanding continuous uptime, the 5kVA UPS can provide expandable runtime with optional BP192V12RT3US external battery pack (sold separately). Battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries.

Economy Mode Helps the Environment and Your Cash Flow

Operates with >98% full-load efficiency in optional economy mode significantly reducing BTU heat output and operating energy costs.

Intuitive Front-Panel Interface offers Convenient Monitoring

Front-panel LEDs indicate line power, AC output, On-battery mode, and Fault conditions. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration.

Pre-installed WEBCARDLXMINI Network Interface Offers 24/7 Access

Pre-installed WEBCARDLXMINI interface, which enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. Advanced Communications Ports USB and DB9 ports with included cabling enable data-saving unattended shutdown of connected systems when used with Tripp Lite's free downloadable PowerAlert® software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions. DB9 ports also support basic contact-closure monitoring to report On-battery and Low-battery status for legacy systems.

Versatile Installation Options

Hardware is included for mounting the 3U 5kVA UPS system and included 2U step-down transformer in 5U total rack spaces in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITHD for 2-post rack mounting (qty 2 required) or the optional 2-9USTAND for mounting in an upright tower position.

Product Type

Double Conversion Online UPS
Technical Information

Plug/Connector Type

  • Hardwired
  • NEMA L6-30P

Receptacle Type

  • NEMA L6-30R
  • NEMA L6-20R
  • Hardwired
  • NEMA 5-20R

Receptacle Detail

  • 2 x NEMA L6-30R
  • 2 x NEMA L6-20R
  • 12 x NEMA 5-20R

Overload Protection

Yes

Transfer Time

0 ns

EMI/RFI Noise Filter

Yes

Phase

Single Phase

Application/Usage

  • Network Equipment
  • Telecommunication
  • Mission Critical Equipment
Power Description

Load Capacity

5000 VA/5000 W

Input Voltage

230 V AC

Output Voltage

  • 120 V AC
  • 208 V AC

Input Frequency

60 Hz

Output Frequency

60 Hz

Waveform Type

Pure Sine Wave

Surge Energy Rating

1680 J
Management

Network Management

SNMP/Telnet/SSH

Alarm

UPS Power Condition
Controls/Indicators

Status Indicators

Front Panel LCD Display:

  • Page Up
  • Selectable LCD Display Escape
  • Page Down
  • Enter and Power buttons enable UPS control
  • Detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)

4 Front-panel LEDs:

  • AC input
  • AC output
  • Battery mode
  • Fault conditions
Interfaces/Ports

Serial Port

Yes

EPO Port

Yes

USB (HID Compliant) Port

Yes
Battery Information

DC System Voltage

192 V DC

Number of Batteries

4

Battery Characteristics

Valve-regulated

Battery Chemistry

Lead Acid

Backup/Run Time (Full Load)

5 Minute

Backup/Run Time (Half Load)

14 Minute

Typical Battery Recharge Time

3 Hour

Hot Swappable

Yes

Replaceable Battery

Yes
Environmental Conditions

Maximum Operating Temperature

104°F (40°C)

Storage Temperature

5°F (-15°C) - 122°F (50°C)

Maximum Operating Elevation

6562 ft

Sound Emission

67 dB

Thermal Dissipation

307.72 W
Physical Characteristics

Height

8.7"

Width

17.5"

Depth

30"

Rack Height

3U

Form Factor

Rack/Tower

Weight (Approximate)

117.51 lb
Miscellaneous

Package Contents

  • SmartOnline SU5KRT3UTF 5kVA Rack/Tower UPS
  • Pre-installed WEBCARDLXMINI Network Management Card
  • 2 x Hardwire Strain Reliefs
  • USB Cable
  • RS-232 Cable
  • Rack-mounting Hardware
  • Owner's Manual
  • L6-30P Power Cable
  • Step-down Transformer

Software Included

PowerAlert

Energy Star

Yes

Environmentally Friendly

Yes

Country of Origin

Taiwan

TAA Compliant

Yes
Warranty

Limited Warranty

2 Year